Sign In | Join Free | My ccnmag.com |
|
Brand Name : Mindray
Model Number : 8200-20-19903 V.A 8200-30-19902
MOQ : 1pcs
Payment Terms : T/T(wire transfer), Western Union, Paypal
Delivery Time : 3-5 working days
Packaging Details : Carton
Product Name : Power Supply Board 8200-20-19903 V.A 8200-30-19902 For Mindray PM8000 Patient Monitor
Brand : Mindray
Part No : 8200-20-19903 V.A 8200-30-19902
MOQ : One piece
Warranty : 90 days
Condition : Work in good
Voltage : 100/240 (V) AC, 50/60 (Hz)
Pmax : 100 VA
FUSE : T 1.6A
Delivery Method : DHL,UPS ,Fedex
Mindray PM8000 Patient Monitor Power Supply Board 8200-20-19903 V.A 8200-30-19902
Mindray PM8000 Patient Monitor Power Supply Board 8200-20-19903 V.A 8200-30-19902 brief introduction
The Mindray PM8000 patient monitor power board is a component of the monitor and is responsible for powering various circuits and modules
within the device. Regulates the input power and provides the appropriate voltage and current to ensure proper operation of the monitor.
Power supply board typically consist of transformers, rectifiers, capacitors, voltage regulators, and various other electronic components. It is used
to convert the AC current from the plug into DC current that the monitor can use.
The power supply board also includes a protection circuit to protect the monitor from damage in the event of a power outage or power surge. This
may include overvoltage protection, undervoltage protection, and overvoltage protection.
Overall, the power supply board plays a crucial role in the reliable operation of the Mindray PM8000 patient monitor, ensuring that it continues to
receive power and can provide accurate patient monitoring data
Mindray PM8000 Patient Monitor Power Supply Board 8200-20-19903 V.A 8200-30-19902 Specification
Product Name | Mindray PM8000 Patient Monitor Power Supply Board 8200-20-19903 V.A 8200-30-19902
|
Brand | Mindray |
Part No | 8200-20-19903 V.A 8200-30-19902 |
Application | Mindray PM8000 Patient Monitor |
Voltage | 100/240 (V) AC, 50/60 (Hz) |
Pmax | 100 VA |
FUSE | T 1.6A |
MOQ | One piece |
Warranty | 90 days |
Connect the Power Cables
Steps to connect the AC power cord:
1.Make sure that the AC power supply meets the following specifications: 100 ~ 240 V AC, 50/60 Hz.
2.Use the power cable supplied with the monitor. Connect the power cable to the INPUT interface of the monitor (⑤connect it in
Figure 1-6). Connect the other end of the power cord to a grounded three-phase electrical outlet.
3.If necessary, connect the ground wire
NOTE Make sure the power light is now on. If it does not turn on, check the local power supply. If the problem persists, contact your local
customer service center. Batteries must be charged after transport or storage. If the power supply is not properly connected before turning on the
monitor, the monitor may not operate properly due to insufficient power. Connect the power supply to charge the battery.
Detailed Photo
Thank you so much for your attention .If you're interested in Power Supply Board 8200-20-19903 V.A 8200-30-19902 For Mindray PM8000
Patient Monitor ,feel free to contact us .Thank you .
![]() |
8200-20-19903 V.A 8200-30-19902 Power Supply Board For Mindray PM8000 Patient Monitor Images |