Brand Name : Mindray
Model Number : 115-006578-00
MOQ : 1
Price : USD
Payment Terms : T/T,Western Union,PayPal
Packaging Details : Carton Packaging
Product Name : Pads Cable with 50 Ohm Test Load
MOQ : 1 Pcs
Model : 115-006578-00
Color : White
Brand : Mindray
Type : Cable
Delivery Time : 3-5 Days
Warrenty : 90 Days
Condition : New
Inventory : In Stock
Mindray BeneHeart D3/D6 Defibrillator Machine Pads Cable with 50 Ohm Test Load 115-006578-00
Description
The 50 ohm test load of Mindray monitor electrode cable is usually used to detect the signal transmission performance of ECG cables and lead wires. ECG signal transmission needs to match the characteristic impedance of the cable (usually 50 ohms) to reduce signal reflection and interference. The role of the cable is to simulate the real human body impedance (about 50-100 ohms), test the signal stability, noise level and anti-interference ability of the ECG lead wire under load, and ensure that the cable and electrode can still maintain performance after long-term use.
How to Use:
- Disconnect power: Make sure the monitor and cable are powered off.
- Connect the load: Connect a 50 ohm resistor across the positive and negative terminals of the ECG lead wire.
- Turn on the monitor and select ECG mode. Observe whether the waveform is stable and check for baseline drift, noise or signal loss.
- Use a signal generator to input a standard amplitude (such as a 1mV/25Hz sine wave) to confirm whether the waveform amplitude and frequency displayed by the monitor are normal.
- Check whether the lead-off alarm function is triggered normally.
Notice:
- Safety first: Avoid touching the patient connection terminals during testing to prevent risk of electric shock.
- Regular calibration: Load testing is recommended every 6 months.
- Documentation: Save test results for medical device maintenance audits.
Brand | Mindray |
Model | 115-006578-00 |
Include | Pads Cable with 50 Ohm Test Load |
Condition | New Original |
Warranty | 90 days |
Application | Mindray BeneHeart D3/D6 Defibrillator |
Type | Cable |
Package | Bag |
Payment | T/T, Western Union, PayPal |
Delivery | 3-5 days |
Warranty
Warranty period: 90 days
We provide warranty for both new and used equipment. Different equipment has different warranty periods. You can contact us to check the warranty details.
Delivery Details
Express delivery method: DHL, FedEx, UPS, etc.
Once payment is completed, we will immediately deliver the product to you quickly and safely. And the delivery date is about 3-5 working days, the shipping cost depends on your country and region.
If your delivery date is longer than expected, or you want to know the shipping details, you can contact us at any time.
Quality
Whether it is new equipment or old equipment, our engineers will conduct a comprehensive inspection before arranging delivery, and we have a 3 month warranty period, so you can purchase with confidence.
Warning
1. It's must use the correct electrical outlet to avoid damage or malfunction.
2. Try to avoid long-term storage, especially in high temperature and high humidity environments.
3. Do not use high-temperature, high-pressure vapour or ionizing radiation as disinfection methods.
4. Do not use chloric disinfectant such as chloride, sodium hypochlorite etc.
5. Please keep it away from water and fire.
We also provide other medical equipment and accessories. If you have any other needs or any questions about this product, please feel free to contact us, we will reply you as soon as possible.
![]() |
Mindray BeneHeart D3/D6 Defibrillator Machine Pads Cable with 50 Ohm Test Load 115-006578-00 Images |